Skip to main content

Environmental Tests - Soil - Radiation

Gross Alpha or Gross Beta
< Return to Table of Contents

 

Gross Alpha or Gross Beta

Matrix

Soil

Method

EPA 900.0

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

65.00



Gross Alpha and Gross Beta
< Return to Table of Contents

Gross Alpha and Gross Beta

Matrix

Soil

Method

EPA 900.0

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

81.00



Gamma Emitting Isotopes
< Return to Table of Contents

Gamma Emitting Isotopes
Be-7, Na-22, Na-24, Cl-38, K-40, Ar-41, K-42, Sc-44, Ti-44, Sc-46, V-48,

Cr-51, Mn-54, Co-56, Mn-56, Co-57, Co-58, Fe-59, Co-60, Cu-64, Ni-65,

Zn-65, Cu-67, Zn-69m, Se-75, As-76, Br-82, Rb-83, Br-84, Kr-85, Kr-85m, Sr-85, Kr-87, Kr-88, Rb-88, Y-88, Kr-89, Rb-89, Zr-89, Mo-90, Sr-91,

Y-91m, Sr-92, Y-92, Sr-93, Y-93, Nb-94, Y-94, Nb-95, Nb-95m, Tc-95,

Zr-95, Nb-96, Tc-96, Nb-97, Zr-97, Mo-99, Tc-99m, Ru-103, Rh-105,

Ru-106, Ag-108m, Cd-109, Ag-110m, Sn-113, Sb-122, I-124, Sb-124,

I-125, Sb-125, Xe-125, I-126, Sb-126, I-129, I-130, I-131, Xe-131m, I-132, Te-132, Ba-133, I-133, Xe-133, Xe-133m, Cs-134, I-134, I-135, Xe-135,

Xe-135m, Cs-136, Cs-137, Cs-138, Xe-138, Ba-139, Ce-139, Ba-140,

La-140, Ce-141, Ce-143, Ce-144, Nd-147, Eu-152, Gd-153, Eu-154, Eu-155, Eu-156, Yb-169, Ta-178, Hf-181, Ta-182, W-187, Ir-192, Au-198, Hg-203, Tl-208, Pb-210, Bi-211, Pb-211, Bi-212, Pb-212, Bi-214, Pb-214, Rn-219, Ra-226, Th-227, Ac-228, Pa-231, Th-231, Th-232, Pa-234, Pa-234m,

Th-234, U-235, U-238, Am-241, Cm-243

Matrix

Soil

Method

EPA 901.1

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

112.00



Radium 226
< Return to Table of Contents

Radium 226 Requires Alpha Spectroscopy Preparation procedure.

Matrix

Soil

Method

EPA 903.1

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

109.00



Radium 228
< Return to Table of Contents

Radium 228 Requires Alpha Spectroscopy Preparation procedure.

Matrix

Soil

Method

EPA 904.0

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

88.00



Uranium Isotopes by Alpha Spectroscopy
< Return to Table of Contents

Uranium Isotopes by Alpha Spectroscopy Includes Uranium 234, Uranium 235, and Uranium 238 Requires Alpha Spectroscopy Preparation procedure.

Matrix

Soil

Method

DOE-RESL A-20
Alpha Spectroscopy

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

68.00



Plutonium Isotopes
< Return to Table of Contents

Plutonium Isotopes Includes Plutonium 238 and Plutonium 239 Requires Alpha Spectroscopy Preparation procedure.

Matrix

Soil

Method

DOE-RESL A-20
Alpha Spectroscopy

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

65.00



Thorium Isotopes
< Return to Table of Contents

Thorium Isotopes Includes Thorium 228, Thorium 230, and Thorium 232 Requires Alpha Spectroscopy Preparation procedure.

Matrix

Soil

Method

DOE-RESL A-20
Alpha Spectroscopy

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

70.00



Strontium 89 or Strontium 90
< Return to Table of Contents

Strontium 89 or Strontium 90

Matrix

Soil

Method

EPA 905.1

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

118.00



Tritium
< Return to Table of Contents

Tritium

Matrix

Soil

Method

EPA Azeotropic Distillation

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

79.00



Alpha Spectroscopy Preparation Procedure
< Return to Table of Contents

 
Alpha Spectroscopy Preparation Procedure

Matrix

Soil

Method

DOE-RESL A-20
Pyrosulfate Fusion

Sample Size Container

400 gram Plastic Tub

Preservation

None

Holding Time

180 days

Fee

123.00