Skip to main content

Environmental Tests - Drinking Water - Inorganic

Bicarbonate-Carbonate, with Alkalinity
< Return to Table of Contents

Bicarbonate-carbonate, with alkalinity

Matrix

Water

Method

Standard Methods 2320B

Sample Size Container

1 Quart Plastic Container

Preservation

4 °C

Holding Time

14 Days



Bicarbonate-Carbonate, without Alkalinity
< Return to Table of Contents

Bicarbonate-carbonate, without alkalinity

Matrix

Water

Method

Standard Methods 2320B

Sample Size Container

1 Quart Plastic Container

Preservation

4 °C

Holding Time

14 Days


Conductance
< Return to Table of Contents

Conductance

Matrix

Water

Method

Standard Methods 2510B

Sample Size Container

1 Quart Plastic Container

Preservation

4 °C

Holding Time

28 Days


Nitrite
< Return to Table of Contents

Nitrite as Nitrogen

Matrix

Water

Method

EPA 353.2

Sample Size Container

100 ml Plastic Container

Preservation

4 °C

Holding Time

48 Hours



pH
< Return to Table of Contents

pH

Matrix

Water

Method

EPA 150.1

Sample Size Container

1 Quart Plastic Container

Preservation

none

Holding Time

Immediate analysis required.



Residue Chlorine, Total & Free
< Return to Table of Contents

Residual Chlorine, Total & Free

Matrix

Water

Method

Standard Methods 2540B

Sample Size Container

1 Quart Plastic Container

Preservation

none

Holding Time

Immediate analysis required.



Routine Water Group
< Return to Table of Contents

Routine Water Group pH, Conductance, Alkalinity, Chloride, Sulfate, Fluoride, Nitrate, Total Dissolved Solids

Matrix

Water

Method

EPA 150.1, 300.0,353.2, Standard Methods 2320B, 2510B, 1030F

Sample Size Container

1 Quart Plastic Container

Preservation

4 °C

Holding Time

14 Days



Solids, Total Dissolved
< Return to Table of Contents

Solids, Total Dissolved, Calculated

Matrix

Water

Method

Standard Methods 1030F

Sample Size Container

1 Quart Plastic Container

Preservation

4 °C

Holding Time

14 Days



Solids, Total Dissolved
< Return to Table of Contents

Solids, Total Dissolved, Determined

Matrix

Water

Method

Standard Methods 2540C

Sample Size Container

1 Quart Plastic Container

Preservation

4 °C

Holding Time

14 Days




Turbidity
< Return to Table of Contents

Turbidity

Matrix

Water

Method

EPA 180.1

Sample Size Container

1 Quart Plastic Container

Preservation

4 °C

Holding Time

48 Hours